Description
VpCI®-705 is a triple-function fuel additive: corrosion inhibitor, fuel stabilizer and water emulsifier in one. Dosed at 0.1 to 0.15 % into gasoline, diesel, gasohol or alcohol fuel it protects the tank, lines, pump and upper cylinder in the liquid, interface and vapor phases, and it does not attack rubber gaskets or plastics. The 5-gallon pail treats roughly 3,300 to 5,000 gallons of fuel.
Stored fuel separates water, the water sits at the tank bottom and the interface, and the vapor space above the fuel rusts. VpCI-705 emulsifies the free water so it burns off, stabilizes the fuel against degradation in storage, and puts a vapor-phase inhibitor into the head space. It protects aluminum, die-cast alloys, zinc, tinplate, copper, ferrous alloys, cast iron and solder, and can be fed continuously or added intermittently. Cortec also fogs the concentrate into empty tanks for storage and shipment. It carries a General Motors approval (GM part number 10661800) and EPA identification number 1733-0002 and in the Cortec Product Consultation Guide is rated 5, immersion service, on all eight listed metals.
Typical applications
- Gasoline, diesel and gasohol fuel tanks
- Carburetors and fuel pumps
- Upper engine cylinder components
- Gas and gas-condensate transmission lines
- Continuous or intermittent treatment
- Standby generator and fire-pump diesel tanks
- Fuel blending and bulk storage facilities
- Seasonal and stored equipment fuel systems
- Empty fuel tanks shipped or warehoused before assembly
- Liquefied gas storage tanks
How to apply VpCI-705
- In-use fuel tanks. Add VpCI-705 to the fuel at the blending facility, the storage tank or directly to the equipment tank at 0.1 to 0.15 % by volume of the tank, about 13 to 19 fl oz per 100 gallons of fuel. Refuelling mixes it.
Service Dosage In-use fuel tanks 0.1–0.15 % of tank volume Empty tank storage or shipment Fog 1.5 oz concentrate per 10 US gal tank volume (45 mL per 37 L) Sales gas and gas-condensate lines ¼ to ½ pint per million cubic feet of gas Liquid gas tanks 100–200 ppm - Empty tanks for storage or shipment. Clean to SSPC-SP-1; a 10 to 20 % solution of VpCI-414 works, then dry completely. Fog VpCI-705 concentrate into the tank at 1.5 oz per 10 gallons of tank volume, covering as much internal surface as possible, and close the tank.
- Equipment. Spray at full strength with conventional equipment such as Graco Delta Spray or LT series guns or the Graco Finex #289258. Wet film is generally under 1 mil (25 µm) and coverage is about 770 to 790 ft² per gallon (18 to 19 m²/L).
- Gas lines and liquid gas tanks. Inject at the rates in the table; treatment can be continuous or intermittent.
- Drying and removal. None. The film stays in the fuel system and burns with the fuel; a fogged tank is simply filled and put into service.
- Storage. Keep sealed.
Where it fits in the Cortec line
VpCI-705 is the fuel-side product. For the oil side of the same engine or generator, M-529 goes into the crankcase and VpCI-329 or VpCI-322 into hydraulic and gearbox oils; VpCI-337 fogs the enclosure around it. A VpCI-705 Bio grade is available, and Cortec’s VpCI-706 is the ferrous-metal additive developed specifically for diesel and biodiesel; ask us about either. Browse the full Cortec VpCI line.
Field notes
A U.S. Air Force base in Japan preserved about 20 million dollars’ worth of airfield damage-repair vehicles parked in an open field: VpCI-415 pressure wash, VpCI-369 D on hinges, ElectriCorr VpCI-239 on electricals, VpCI-105 and VpCI-111 emitters in cabs and fuse boxes, VpCI-391 in engine compartments, VpCI-386 CMA over the paint and VpCI-705 in the fuel. Other Pacific bases asked to copy it. (Cortec Case History #557)
A state-owned deepwater drilling contractor in Vietnam cold-stacked a rig with a full treatment schedule: VpCI-326 and VpCI-329 at 20% and M-531 at 5% in gearboxes, mud pumps and engines; VpCI-705 at 100 ppm in fuel; VpCI-649 BD at 0.5% in fresh-water systems; and VpCI-308 and VpCI-609 fogged into empty tanks and pipelines. (Cortec Case History #575)
A coastal heavy-equipment dealer in Indonesia had fuel tanks rusting on nearly every stored machine. Tanks are de-rusted inside with VpCI-423, rinsed with 10% VpCI-416, flushed with diesel and dosed with VpCI-705 Bio in the fuel; no more grinding, and the method was adopted across tank types. (Cortec Case History #670)
Specifications
| Dosage — in-use fuel tanks | 0.1–0.15% per volume of tank to be protected |
|---|---|
| Dosage — dry tank storage/shipment | 1.5 oz per 10 U.S. gallons tank volume |
| Dosage — sales gas / gas-condensate lines | ¼ to ½ pint per million cubic feet of gas |
| Dosage — liquid gas tanks | 100–200 ppm |
| Functions | Corrosion inhibitor, fuel stabilizer, water emulsifier |
| Fuels | Gasoline, diesel, gasohol mixtures and alcohol fuels |
| Phases protected | Liquid, interface and vapor |
| Metals | Aluminum, die-cast alloys, zinc, tinplate, copper, ferrous alloys, cast iron and solder |
| Also protects | Non-metallics such as rubber gaskets and plastics |
| Consultation guide rating | 5 – immersion, all eight metals |
| Approval | General Motors approved, part number 10661800; EPA identification #1733-0002 |
| Tests | Passes MIL-PRF-25017G category 1 rust test and ASTM D665 rust test |
| Flash point | 171 °F (77 °C) |
| Density | 6.7–6.9 lb/gal (0.80–0.83 kg/L) |
| Non-volatile content | 17–23% |
| Fogging wet film | Less than 1 mil (25 µm) |
| Fogging coverage | 770–790 ft²/gal (18–19 m²/L) |
| Surface preparation (empty tanks) | SSPC-SP-1; clean with VpCI-414 at 10–20 % |
| Also available | VpCI-705 Bio grade |
| Military specification | Passes the MIL-PRF-25017G Category 1 rust test (Cortec PDS); not a QPL listing |
| Size | 5 Gallon Pail |
| Shipping weight | 39 lb (17.7 kg) |
| Availability | In stock |